Difference between revisions of "CM-T43: Linux: Known Issues"
Line 1: | Line 1: | ||
{{IssueCategory|RTC| | {{IssueCategory|RTC| | ||
− | * RTC time and date is not maintained when unit is unplugged from power supply, even if an RTC backup battery is installed | + | * RTC time and date is not maintained when unit is unplugged from power supply, even if an RTC backup battery is installed. |
− | :''' | + | :'''Fixed in U-Boot v2016.01-cm-t43-1''' |
− | |||
− | |||
− | |||
− | |||
}} | }} | ||
{{IssueCategory|OPP| | {{IssueCategory|OPP| | ||
* U-Boot versions 0.97 and below do not modify the PMIC voltages. The PMIC retains its settings between resets, and as a result if CM-T43 is switched to a low performance OPP (below 800 Mhz), on reset U-Boot will be using low performance voltage settings for a high performance CPU frequency and may not finish booting. | * U-Boot versions 0.97 and below do not modify the PMIC voltages. The PMIC retains its settings between resets, and as a result if CM-T43 is switched to a low performance OPP (below 800 Mhz), on reset U-Boot will be using low performance voltage settings for a high performance CPU frequency and may not finish booting. | ||
− | :''' | + | :'''Fixed in U-Boot v2016.01-cm-t43-1''' |
− | |||
}} | }} | ||
[[Category:Linux]] | [[Category:Linux]] | ||
[[Category:CM-T43]] | [[Category:CM-T43]] |
Revision as of 14:35, 14 February 2016
RTC |
|
OPP |
|