SB-FX6: HOWTO: CAN Connection
Description
The CAN bus interface available with SB-FX6 is accessible through the P61 100mil header. Use jumper wires to connect your CAN node with SB-FX6 CAN bus interface as outlined in the table below.
P61 Pin Signal Name Description 1 CAN_GND Connect to GND terminal your CAN bus interface 5 CAN_L Connect to CAN_L terminal your CAN bus interface 3 CAN_H Connect to CAN_H terminal your CAN bus interface 2 CAN_VCC (5V) If your CAN bus interface requires 5V power, Connect this pin to your CAN bus terminal. Otherwise, Do not use.
120Ω CAN bus termination
CAN bus termination on a node is required with some CAN bus topologies while forbidden with others. SB-FX6 board revision 1.2 (or later) supports enabling/disabling the 120Ω CAN bus termination implemented onboard SB-FX6. Set the bus termination most recommended for your CAN bus topology using P61 connector.
Revisions 1.1 and 1.0 of SB-FX6 do feature CAN bus termination |
- Place a jumper cap between pins 4 and 6 of P61 to enable 120Ω CAN bus termination.
- Remove the jumper cap to from pins 2 and 3 of P61 to disable 120Ω CAN bus termination.